Search results for " patient monitoring"

showing 10 items of 21 documents

Towards Improved Healthcare Performance: Examining Technological Possibilities and Patient Satisfaction with Wireless Body Area Networks

2009

Published version of an article from the journal: Journal of Medical Systems. he original publication is available at Springerlink. http://dx.doi.org/10.1007/s10916-009-9291-8 This paper investigates the benefits of using less intrusive wireless technologies for heart monitoring. By replacing well established heart monitoring devices (i.e. Holter) with wireless ECG based Body Area Networks (BAN), improved healthcare performance can be achieved, reflected in (1) high quality ECG recordings during physical activities and (2) increased patient satisfaction. A small scale clinical trial was conducted to compare both technologies and the results illustrate that the wireless ECG monitor was able …

AdultMaleTelemedicineAdolescentComputer scienceRemote patient monitoringmedicine.medical_treatmentmedia_common.quotation_subjecteducationMedicine (miscellaneous)Health InformaticsHealth informaticsYoung AdultPatient satisfactionHealth Information ManagementmedicineHumansWirelessVDP::Medical disciplines: 700::Health sciences: 800::Health service and health administration research: 806ComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMSQuality (business)cardiovascular diseasesChildAgedmedia_commonbusiness.industryLocal area networkArrhythmias CardiacVDP::Technology: 500::Information and communication technology: 550Middle AgedLocal Area Networksequipment and suppliesTelemedicineRisk analysis (engineering)Patient SatisfactionElectrocardiography AmbulatoryFemaleCardiac monitoringbusinessTelecommunicationsInformation Systems
researchProduct

Photoplethysmography system for blood pulsation detection in unloaded artery conditions

2012

Photoplethysmography (PPG) is an optical method of blood pulsation recording and has been extensively studied for decades. Recently PPG is widely used in the medical equipment for patient monitoring and in laboratories for research and physiological studies. In spite of the technological progress in the field of medical equipment, there are no generally accepted standards for clinical PPG measurements up to date. One of the most important factors affecting PPG waveform is the contact pressure between tissue and PPG probe. The aim of the current study was to develop and evaluate a system for software-assisted PPG signal acquisition from the unloaded artery. Novel PPG waveform derived Optimal…

Blood pressureTransmural pressuremedicine.anatomical_structureComputer scienceRemote patient monitoringPhotoplethysmogrammedicinePlethysmographWaveformsense organsArteryBiomedical engineeringSPIE Proceedings
researchProduct

Analysis of the written handover process during shift changes within the hospital

2008

This study assesses the ergonomic quality of a new writing format used for the written transmission of activity during a nurse’s handover in a hospital. This format called “targeted or focussed transmission” comes from a new prescription of hospital management designed to improve the written handover process. Our research focused on the information filtering process for each patient concerned by a shift handover. A three step methodology was designed, with the participation of 9 nurses in charge of 70 patients : (1) nursing work analysis before the handover, (2) oral handover analysis, (3) written handover analysis. Results show that the new writing format does not match the nurses’ needs t…

Cognitive modelMultimediaRemote patient monitoringbusiness.industryProcess (engineering)media_common.quotation_subjectGeneral EngineeringHuman factors and ergonomicscomputer.software_genreHandoverPatient stateGeneral Earth and Planetary SciencesMedicineQuality (business)Medical prescriptionbusinesscomputerGeneral Environmental Sciencemedia_commonActivites
researchProduct

MEDiSN

2010

Staff shortages and an increasingly aging population are straining the ability of emergency departments to provide high quality care. At the same time, there is a growing concern about hospitals' ability to provide effective care during disaster events. For these reasons, tools that automate patient monitoring have the potential to greatly improve efficiency and quality of health care. Towards this goal, we have developed MEDiSN , a wireless sensor network for monitoring patients' physiological data in hospitals and during disaster events. MEDiSN comprises Physiological Monitors (PMs), which are custom-built, patient-worn motes that sample, encrypt, and sign physiological data and Relay Po…

Computer scienceRemote patient monitoringNetwork packetbusiness.industryQuality of serviceTestbedComputer securitycomputer.software_genreEncryptionHardware and ArchitectureHealth careWirelessbusinesscomputerWireless sensor networkSoftwareACM Transactions on Embedded Computing Systems
researchProduct

The RFID technology for neurosciences: feasibility of limbs' monitoring in sleep diseases.

2009

This contribution investigates the feasibility of the passive UHF RF identification technology for the wireless monitoring of human body movements in some common sleep disorders by means of passive tags equipped with inertial switches. Electromagnetic and mechanical models as well as preliminary experimentations are introduced to analyze all the significant issues concerning the required power, the tag antenna design, the read distance, and the expected biosignals collected by the interrogation device.

Computer scienceRemote patient monitoringRadio WavesPolysomnographytag antennaRFID sensor Human health monitoringAccelerometerRF identification (RFID)MotionRestless Legs SyndromemedicineWirelessHumansTelemetryaccelerometer; RF identification (RFID); sensor network; sleep disorder; tag antennaElectrical and Electronic Engineeringsensor networksleep disorderSleep disorderbusiness.industrySettore ING-INF/02 - Campi ElettromagneticiExtremitiesGeneral MedicineModels Theoreticalmedicine.diseaseComputer Science ApplicationsNocturnal Myoclonus SyndromeaccelerometerRadio frequencySleep (system call)TelecommunicationsbusinessWireless sensor networkComputer hardwareAlgorithmsBiotechnologyIEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society
researchProduct

MEDiSN

2008

Staff shortages and an increasingly aging population are straining the ability of emergency departments to provide high-quality care. Moreover, there is a growing concern about the ability of hospitals to provide effective care during disaster events. Tools that automate patient monitoring would greatly improve efficiency, quality of care, and the volume of patients treated. Towards this goal, we have developed MEDiSN, a wireless sensor network for monitoring patients' vital signs in hospitals and disaster events. MEDiSN consists of Patient Monitors which are custom-built, patient-worn motes that sample, compress and secure medical data, and Relay Points that form a static multi-hop wireles…

Computer sciencebusiness.industryRemote patient monitoringQuality of serviceVital signsVolume (computing)Sample (statistics)Computer securitycomputer.software_genreWirelessbusinesscomputerCollection Tree ProtocolWireless sensor networkProceedings of the 6th ACM conference on Embedded network sensor systems
researchProduct

Real-Time Localization of Epileptogenic Foci EEG Signals: An FPGA-Based Implementation

2020

The epileptogenic focus is a brain area that may be surgically removed to control of epileptic seizures. Locating it is an essential and crucial step prior to the surgical treatment. However, given the difficulty of determining the localization of this brain region responsible of the initial seizure discharge, many works have proposed machine learning methods for the automatic classification of focal and non-focal electroencephalographic (EEG) signals. These works use automatic classification as an analysis tool for helping neurosurgeons to identify focal areas off-line, out of surgery, during the processing of the huge amount of information collected during several days of patient monitori…

ElectrodiagnòsticRemote patient monitoringComputer science02 engineering and technologyElectroencephalographylcsh:Technologylcsh:Chemistryepileptogenic focus03 medical and health sciences0302 clinical medicineClassifier (linguistics)0202 electrical engineering electronic engineering information engineeringmedicineGeneral Materials ScienceEpilepsy surgeryLatency (engineering)Field-programmable gate arrayInstrumentationThroughput (business)lcsh:QH301-705.5FPGAFluid Flow and Transfer Processesmedicine.diagnostic_testbusiness.industrylcsh:TProcess Chemistry and Technologyreal-time implementationepileptic eeg signal classificationGeneral EngineeringProcess (computing)Pattern recognitionelectroencephalogramlcsh:QC1-999Computer Science Applicationsfpgalcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040epileptic EEG signal classificationepilepsy020201 artificial intelligence & image processingEnginyeria biomèdicaArtificial intelligenceElectroencefalografiabusinesslcsh:Engineering (General). Civil engineering (General)030217 neurology & neurosurgerylcsh:Physics
researchProduct

Flat panel displays for medical monitoring systems

2005

Flat panel displays are ideal for demanding hospital and clinic applications like vital sign monitoring and bedside administration. They take up much less space than conventional monitors (CRT based) and can be wall-mounted, cart-mounted or used on a desk stand. User friendly interface demands easy to use input device, rotary position encoders and touch screen panels offers simplicity replacing bulky keyboards. This article will present an overview about today's medical monitoring systems tendencies, describing as an example, a custom medical monitoring module developed to be integrated in an assisted ventilation system.

EngineeringUser Friendlybusiness.industryRemote patient monitoringSimplicity (photography)Interface (computing)Monitoring systemInput devicebusinessEncoderComputer hardwareDesk
researchProduct

Effect of Motion Artifact on Digital Camera Based Heart Rate Measurement

2017

International audience; Depression is one of the most prevalent mental disorders, burdening many people world-wide. A system with the potential of serving as a decision support system is proposed, based on novel features extracted from facial expression geometry and speech, by interpreting non-verbal manifestations of depression. The proposed system has been tested both in gender independent and gender based modes, and with different fusion methods. The algorithms were evaluated for several combinations of parameters and classification schemes, on the dataset provided by the Audio/Visual Emotion Challenge of 2013 and 2014. The proposed framework achieved a precision of 94.8% for detecting p…

Engineeringbusiness.product_category[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingRemote patient monitoringMotion artifact effect02 engineering and technology01 natural sciencesMotion (physics)Field (computer science)Photoplethysmography signalComputer vision[ SDV.IB ] Life Sciences [q-bio]/Bioengineering[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingDigital cameraSkinPatient monitoringDigital cameraremote health monitoringCamerasBiomedical technologyHeart rate measurement[SDV.IB]Life Sciences [q-bio]/BioengineeringArtifactsAlgorithms[ INFO ] Computer Science [cs]0206 medical engineeringHeart rateCardiology[INFO] Computer Science [cs]010309 opticsMotionDatabases0103 physical sciences[INFO]Computer Science [cs]Heart rate measurement methodPhotoplethysmographyBiomedical measurementLighting[SDV.IB] Life Sciences [q-bio]/BioengineeringArtifact (error)Digital camerasMAHNOB-HCI databasebusiness.industry020601 biomedical engineeringMotion artifacts[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/ImagingFace (geometry)FaceState (computer science)Artificial intelligencebusiness
researchProduct

The analysis of blood flow changes under local anesthetic input using non-contact technique

2010

In this work photoplethysmography imaging (PPGI) technique was used to obtain blood flow changes in human skin under regional anesthesia (RA). PPGI was evaluated from video taken by video camera for 26 patients 2 minutes before and immediately after RA, using custom developed software. Results showed that blood flow obtained by PPGI increases immediately after RA effect and the amplitude of PPGI showed correlation with temperature changes in human skin (r=0.8±0.14, p<0.0001). We found that PPGI technique can be usable for non-contact monitoring of quality of RA.

Local anestheticmedicine.drug_classRegional anesthesiabusiness.industryRemote patient monitoringPhotoplethysmogramAnesthesiamedicinePlethysmographBlood flowbusinessBiomedical engineering2010 3rd International Conference on Biomedical Engineering and Informatics
researchProduct